KRAMER: SIMPLE CREATIVE TECHNOLOGY
Using Your TP-300FW FireWire Range Extender
8
Figure 3: Connecting Three TP-300FW Units to Extend the Distance to 200m
1. Connect a FireWire device (for example, a video camcorder) to the FW PORT
on the first TP-300FW unit, and a FireWire device (for example, a PC) to the
FW PORT on the third TP-300FW unit.
2. Connect the CAT 5 STRAIGHT RJ-45 connector on the first TP-300FW unit
to the CAT 5 CROSSED RJ-45 connector on the second TP-300FW unit.
3. Connect the CAT 5 STRAIGHT RJ-45 connector on the second TP-300FW
unit to the CAT 5 CROSSED RJ-45 connector on the third TP-300FW unit
1
.
4. Be sure that the power on each FireWire device is turned ON.
On the first and third TP-300FW units, the ACTIVE green LED lights
1
Alternatively, connect the CAT 5 CROSSED RJ-45 connector on the first TP-300FW unit to the CAT 5 STRAIGHT RJ-45 connector
on the second TP-300FW unit, and connect the CAT 5 CROSSED RJ-45 connector on the second TP-300FW unit to the CAT 5
STRAIGHT RJ-45 connector on the third TP-300FW unit