60 VP-790 Protocol - API Functions
2.50 IP Address
2.50.1 bySetStaticIPAddr
API index: 111
Sets the static IP address and saves the setting in the SPD immediately.
Input Parameters
Name Type Range Description
Value STRING nnn.nnn.nnn.nnn
String with 15 ASCII
characters /0 terminated
Static IP address
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.50.2 byGetStaticIPAddr
API index: 112
Retrieves the IP address from the SPD.
Input Parameters
Name Type Range Description
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value STRING nnn.nnn.nnn.nnn
String with 15 ASCII
characters /0 terminated
Static IP address
2.51 IP Address Type
2.51.1 bySetDHCPStatus
API index: 115
Choose between IP address type static or DHCP leased and saves the setting in
the SPD immediately.
Input Parameters
Name Type Range Description
Value UWORD32 0: Static
1: DHCP
IP address type
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise