KRAMER: SIMPLE CREATIVE TECHNOLOGY
Using the Isolation Transformer
The grounding conditions are set by trial and error. Check all the options to
work out which option best suits your needs
1
.
5.2.1 Audio Dipswitches
The dipswitches let you set the grounding conditions, as illustrated in Figure 7
and defined in Table 8 for the audio channels.
Figure 7: IN and OUT Grounding Options
Table 8: Audio Dipswitch Settings
2
AUDIO LEFT Description AUDIO RIGHT
1 2 3 2 3 4
ON ON ON Audio IN and OUT are grounded to the chassis ON ON ON
ON ON OFF Audio OUT shield is connected to the common ground,
audio IN shield is left open
ON OFF ON
ON OFF ON Audio IN is connected to chassis, audio OUT is grounded
to the shield
OFF ON ON
OFF ON ON Audio IN and OUT are both grounded to the shield ON ON OFF
Figure 8 and Figure 9 show the balanced and unbalanced audio grounding
schematics respectively.
+
-
G
Figure 8: Balanced Audio Grounding Schematics
1 In most applications the ground is not connected
2 Only these combinations are applicable. Other dipswitch settings are insignificant
Kommentare zu diesen Handbüchern