SIERRA VIDEO SYSTEMS SP-14
10 2.2.4. SDI Input Format: SD-SDI HD-SDI YCbCr 4:2:2 serial digital component video 3G-SDI 4:2:2 and 4:4:4 serial digital component video I
11 2.3. Genlock Vertical frame synchronisation is provided. The frame signal can be derived from the dedicated analogue Genlock input
12 FLOW CHART FOR SP-14 OPERATION 3.1. Correct Installation Order Start 1 - Connect to display device 2 - Connect audio output
13 FRONT PANEL CONTROL 4.1. Menu Tree Start up Screen Main Menu MEMC/FRC Settings FRC Level MEMC Exclusion Zone Enable MEMC Mask
14 Aspect Ratio AFD Mode AFD Default/Forced AFD Source Trim Width % Trim Height % Pan Le
15 IP Address Type DHCP status IP address Subnet Mask Gateway IP MAC Address Miscellaneous Select Test Pattern Status Display Mode Channel L
16 4.2. Introduction The front panel displays information via a 4 line by 40 character display. Kramer Electronics Ltd. SP-14 Software Ver:
17 4.3. Start-up Screen The start-up screen shows the currently selected input signal, output resolution and provides information on the locking st
18 FRC level General: Only enables RGME mode when scene is quite busy, and also enables blend when the scene looks too busy. FRC levels Drama, Talk
19 Outlier A part of the image that is moving independently of the dominant motion Cost Cost factors are relative weightings used when assessi
2 SP-14 Operating Instructions Version K-1.6
20 4.6. Time Code Settings SP-14 processes time code information from SD formats on the analogue Composite, S-Video and Component in
21 TC Output Load Set the output time code start value, which is then triggered either manually or through the synchronisation descri
22 4.7. Input Adjust This menu contains adjustments associated with setting up inputs to the unit. Use the Up and Down arrows to scroll to the re
23 Control of the sharpening enhancement. These are peaking filters to improve high-frequency response. Note: setting this control too high o
24 4.7.6. Filters A submenu containing selection options for many image clean-up filters including: CCS Cross Chrominance Suppression filt
25 4.8. Output Adjust This menu contains adjustments associated with setting up the outputs of the unit. Use the up and down arrows to scroll to th
26 4.8.5. ARC Mode Select from Bypass, Anamorphic 25%, Panels/Letterbox 25%, Crop 25%, 14:9, Flex Wide and Custom. Bypass will scale the image
27 4.8.11. Gamma of Display Allows to change the gamma correction to match the gamma of the display. 4.9. SP-14 Audio Audio input channels ar
28 Group 1 Input from SDI, Group 2 Input from SDI An SDI signal may carry 8x two channel audio signals. The SDI receiver used in SP-14 is only cap
29 Similarly, if the rate is increased then more nulls are introduced between the messages. This applies equally whether in Drop/Repeat mode, or d
3 This manual explains how to operate your television broadcast image processor. The product is designed to provide users with a powerful and flexi
30 Incorrect format selection will cause severe color errors or loss of stable picture, incorrect level selection will cause the picture be very dim
31 REMOTE CONTROL WEB SERVER 5.1. Introduction The unit features a web server which connects to a PC web browser via TCP/IP. The menu system of the
32 FIRMWARE UPDATE 6.1. Introduction Firmware can be updated in the field through the USB port allowing feature upgrades and bug fixes. The USB por
33 ENVIRONMENTAL AND EMC 7.1. Recommended Operating Conditions Temperature 0oC to 40oC Humidity (non condensing) 0% to 95% 7.2. Storage T
34 ABBREVIATIONS This section expands abbreviations peculiar to video applications which may be used in this manual. AFD Active Format Descript
4 Contents INTRODUCTION 7 1.1. General Introduction 7 1.1.1. Front Panel Control 7 1.1.2. Rear Panel conectivity 8 1.2. Packing List 8 SYST
5 4.13.5. Factory Reset 30 4.13.6. Unit Configuration 30 4.13.7. Networking(TCP/IP) 30 4.13.8. Presets 30 REMOTE CONTROL WEB SERVER 31 5.1.
6 SAFETY WARNING: 1. THERE ARE NO USER SERVICEABLE PARTS WITHIN THE UNIT. REMOVAL OF THE TOP COVER WILL EXPOSE DANGEROUS VOLTAGES. DO NOT OPERATE
7 INTRODUCTION 1.1. General Introduction SP-14 is a very flexible television broadcast image processor developed to convert between vi
8 1.1.2. Rear Panel conectivity SP-14 uses a very high performance video input front end including true component video support in analogue YPbP
9 SYSTEM DESCRIPTION 2.1. Product Overview SP-14 is designed to accept the following input signals: 2x Composite video via BNC S-Video Y/C via 2x